Abstract
Purpose. We have developed customized maps that relate visual field and optic nerve head (ONH) regions according to individual anatomy. In this study, we aimed to determine feasible map resolution for research use, and to make a principled recommendation of sector size for clinical applications. Methods. Measurement variability in fovea-ONH distance and angle was estimated from 10 repeat OCT scans of 10 healthy people. Errors in estimating axial length from refractive error were determined from published data. Structure-function maps were generated, and customized to varied clinically-plausible anatomical parameters. For each parameter set (n = 210), 200 maps were generated by sampling from ..
View full abstractRelated Projects (2)
Grants
Awarded by Victorian Life Sciences Computation Initiative (VLSCI)
Awarded by Australian Research Council (ARC)
Awarded by Australian Research Council
Funding Acknowledgements
Supported by a Victorian Life Sciences Computation Initiative (VLSCI) Grant VR0052 on its Peak Computing Facility at the University of Melbourne, an initiative of the Victorian Government, Australia, the Australian Research Council (ARC) Linkage Project LP100100250 (with Heidelberg Engineering, GmbH), two ARC Future Fellowships FT0990930 (AMM), and FT0991326 (AT).